Medical imaging of knee kinematics after joint replacement

关节置换后膝关节运动学的医学成像

基本信息

  • 批准号:
    350822-2008
  • 负责人:
  • 金额:
    $ 2.93万
  • 依托单位:
  • 依托单位国家:
    加拿大
  • 项目类别:
    Collaborative Health Research Projects
  • 财政年份:
    2010
  • 资助国家:
    加拿大
  • 起止时间:
    2010-01-01 至 2011-12-31
  • 项目状态:
    已结题

项目摘要

The primary reason for someone to get a knee replacement is to reduce his or her pain due to arthritis. Unfortunately, some people still have considerable pain after the surgery, often in the region of the kneecap (called anterior knee pain). Frequently this pain is attributed to incorrect tracking of the kneecap (patella) on the thigh bone (femur) due to improper component design, incorrect placement of the components, excessively tight soft tissues or poor surgical technique. Currently, the only method most surgeons use to 'look inside' the knee is X-rays, which are two-dimensional images at a single angle of knee flexion. These provide inadequate information to study the movements of the bones. We are proposing to develop a new method to measure the three-dimensional positions of both the bones and components after knee replacement surgery at different flexion angles, using computed tomography (CT). CT produces a 3D image of the patient's knees. The metal components create streaks on the image, making it difficult to identify the bones and components accurately, however we are proposing several ways to address this. We will validate the protocol using reference arrays inserted into cadaveric knee specimens. We will then apply the protocol to patients in order to judge whether or not a recent implant design improves kneecap motion; subsequently, we will compare patients with and without pain. In addition, and in contrast, to CT, we will develop a protocol for two-dimensional fluoroscopic imaging, which is dynamic (i.e. captures a video of movement), inexpensive, widely available and could be applied in
有人替换膝盖的主要原因是减轻因关节炎引起的疼痛。 不幸的是,手术后,有些人通常在膝盖腹肌(称为前膝盖疼痛)中会出现相当大的疼痛。这种疼痛通常归因于由于成分设计不当,组件的放置不正确,软组织过度或较差的手术技术而导致大腿骨(股骨)上膝盖骨(patella)的不正确跟踪。目前,大多数外科医生用来“看”膝盖的唯一方法是X射线,它们是二维图像,单次膝盖屈曲。这些提供了不充分的信息来研究骨骼的运动。 我们建议使用计算机断层扫描(CT)开发一种新方法,以在不同屈曲角度以不同的屈曲角度来衡量骨骼和成分的三维位置。 CT产生患者膝盖的3D图像。金属组件在图像上产生条纹,因此难以准确识别骨骼和成分,但是我们提出了几种解决此问题的方法。我们将使用插入尸体膝关节样本中的参考阵列来验证协议。然后,我们将将该方案应用于患者,以判断最近的植入物设计是否改善了KNEECAP运动;随后,我们将比较有和没有疼痛的患者。此外,与CT相比,我们将开发一种用于二维荧光影像成像的协议,该协议是动态的(即捕获运动视频),廉价,可广泛可用,可以在

项目成果

期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)

数据更新时间:{{ journalArticles.updateTime }}

{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

数据更新时间:{{ journalArticles.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ monograph.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ sciAawards.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ conferencePapers.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ patent.updateTime }}

Anglin, Carolyn其他文献

Changes in knee kinematics following total knee arthroplasty
A novel multi-planar radiography method for three dimensional pose reconstruction of the patellofemoral and tibiofemoral joints after arthroplasty
  • DOI:
    10.1016/j.jbiomech.2011.04.006
  • 发表时间:
    2011-06-03
  • 期刊:
  • 影响因子:
    2.4
  • 作者:
    Amiri, Shahram;Wilson, David R.;Anglin, Carolyn
  • 通讯作者:
    Anglin, Carolyn
Good vs Poor Results After Total Hip Arthroplasty: An Analysis Method Using Implant and Anatomic Parameters With the EOS Imaging System
  • DOI:
    10.1016/j.arth.2015.12.036
  • 发表时间:
    2016-09-01
  • 期刊:
  • 影响因子:
    3.5
  • 作者:
    Bendaya, Samy;Anglin, Carolyn;Skalli, Wafa
  • 通讯作者:
    Skalli, Wafa
Hip resurfacing femoral neck fracture influenced by valgus placement
  • DOI:
    10.1097/blo.0b013e318137a13f
  • 发表时间:
    2007-12-01
  • 期刊:
  • 影响因子:
    4.2
  • 作者:
    Anglin, Carolyn;Masri, Bassam A.;Greidanus, Nelson V.
  • 通讯作者:
    Greidanus, Nelson V.
To Resurface or Not to Resurface the Patella in Total Knee Arthroplasty
  • DOI:
    10.1007/s11999-008-0420-3
  • 发表时间:
    2008-11-01
  • 期刊:
  • 影响因子:
    4.2
  • 作者:
    Helmy, Naeder;Anglin, Carolyn;Masri, Bassam A.
  • 通讯作者:
    Masri, Bassam A.

Anglin, Carolyn的其他文献

{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

{{ truncateString('Anglin, Carolyn', 18)}}的其他基金

Development and Clinical Efficacies of an Innovative Quantitative Intraoperative C-arm System
创新定量术中C形臂系统的开发和临床效果
  • 批准号:
    462233-2014
  • 财政年份:
    2016
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Collaborative Health Research Projects
Development and validation of synthetic bone and soft tissue analogues for surgical training (Phase I)
用于外科训练的合成骨和软组织类似物的开发和验证(第一阶段)
  • 批准号:
    476890-2015
  • 财政年份:
    2015
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Idea to Innovation
Development and Clinical Efficacies of an Innovative Quantitative Intraoperative C-arm System
创新定量术中C形臂系统的开发和临床效果
  • 批准号:
    462233-2014
  • 财政年份:
    2015
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Collaborative Health Research Projects
Biomedical Engineering Industry Forum - University of Calgary
生物医学工程产业论坛-卡尔加里大学
  • 批准号:
    486663-2015
  • 财政年份:
    2015
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Regional Office Discretionary Funds
Development and Clinical Efficacies of an Innovative Quantitative Intraoperative C-arm System
创新定量术中C形臂系统的开发和临床效果
  • 批准号:
    462233-2014
  • 财政年份:
    2014
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Collaborative Health Research Projects
Patellar computer-assisted surgery and intraoperative kinematics
髌骨计算机辅助手术和术中运动学
  • 批准号:
    341839-2008
  • 财政年份:
    2012
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Discovery Grants Program - Individual
UFA Nomination
UFA提名
  • 批准号:
    360021-2008
  • 财政年份:
    2011
  • 资助金额:
    $ 2.93万
  • 项目类别:
    University Faculty Award
Patellar computer-assisted surgery and intraoperative kinematics
髌骨计算机辅助手术和术中运动学
  • 批准号:
    341839-2008
  • 财政年份:
    2011
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Discovery Grants Program - Individual
Patellar computer-assisted surgery and intraoperative kinematics
髌骨计算机辅助手术和术中运动学
  • 批准号:
    341839-2008
  • 财政年份:
    2010
  • 资助金额:
    $ 2.93万
  • 项目类别:
    Discovery Grants Program - Individual
UFA Nomination
UFA提名
  • 批准号:
    360021-2008
  • 财政年份:
    2010
  • 资助金额:
    $ 2.93万
  • 项目类别:
    University Faculty Award

相似国自然基金

星载SAR非沿迹场景匹配曲线成像理论与方法
  • 批准号:
    62331007
  • 批准年份:
    2023
  • 资助金额:
    237 万元
  • 项目类别:
    重点项目
多种动脉硬化标志物顺序响应型探针的构建及精准成像应用研究
  • 批准号:
    22368035
  • 批准年份:
    2023
  • 资助金额:
    32 万元
  • 项目类别:
    地区科学基金项目
血管内皮细胞炎症损伤过程中蛋白质酪氨酸硝化原位荧光成像
  • 批准号:
    22374091
  • 批准年份:
    2023
  • 资助金额:
    50 万元
  • 项目类别:
    面上项目
集成化双比率激活型近红外二区荧光探针用于脑内关联活性氧物种的同步检测与深度成像
  • 批准号:
    22304132
  • 批准年份:
    2023
  • 资助金额:
    30 万元
  • 项目类别:
    青年科学基金项目
精确测定合金析出相微结构参数的定量电镜三维成像方法
  • 批准号:
    12304007
  • 批准年份:
    2023
  • 资助金额:
    30 万元
  • 项目类别:
    青年科学基金项目

相似海外基金

Achieving Sustained Control of Inflammation to Prevent Post-Traumatic Osteoarthritis (PTOA)
实现炎症的持续控制以预防创伤后骨关节炎 (PTOA)
  • 批准号:
    10641225
  • 财政年份:
    2023
  • 资助金额:
    $ 2.93万
  • 项目类别:
Brain Mechanisms of Chronic Low-Back Pain: Specificity and Effects of Aging and Sex
慢性腰痛的脑机制:衰老和性别的特异性和影响
  • 批准号:
    10657958
  • 财政年份:
    2023
  • 资助金额:
    $ 2.93万
  • 项目类别:
ShEEP Request for Two Digital Radiography (DR) Flat Panels
ShEEP 请求购买两台数字放射成像 (DR) 平板
  • 批准号:
    10741714
  • 财政年份:
    2023
  • 资助金额:
    $ 2.93万
  • 项目类别:
Quadriceps Muscle Quality: A Post-Injury Determinant of Knee Function and Health
股四头肌肌肉质量:膝关节功能和健康的损伤后决定因素
  • 批准号:
    10743396
  • 财政年份:
    2023
  • 资助金额:
    $ 2.93万
  • 项目类别:
Reliable AI for Medical Image Reconstruction
用于医学图像重建的可靠人工智能
  • 批准号:
    10687707
  • 财政年份:
    2023
  • 资助金额:
    $ 2.93万
  • 项目类别:
{{ showInfoDetail.title }}

作者:{{ showInfoDetail.author }}

知道了