用于现场X荧光分析的硅漂移探测器读出电路及数字处理算法研究
项目介绍
AI项目解读
基本信息
- 批准号:11905020
- 项目类别:青年科学基金项目
- 资助金额:21.0万
- 负责人:
- 依托单位:
- 学科分类:A30.核技术及其应用
- 结题年份:2022
- 批准年份:2019
- 项目状态:已结题
- 起止时间:2020-01-01 至2022-12-31
- 项目参与者:--
- 关键词:
项目摘要
In-situ X-ray fluorescence detection is an important technical method in the field of nuclear geophysics exploration, and it plays an important role in the development of mineral resources. The traditional X-ray fluorescence detection instrument has the disadvantages of high detection limit, long dead time and significantly reduced energy resolution at high counting rates, which makes it impossible to shorten the measurement period by increasing the fluorescence yield, and it will be impossible to accurately achieve mineral accuracy or fast measurement. In response to this problem, this project is based on a new silicon drift detector to build a complete silicon drift X-ray fluorescence detection mathematical model and establish a detector energy response function, and it will study high-resolution silicon drift detector technology, fast low-noise readout technology, and all-digital high-speed nuclear pulse acquisition and processing technologies. Based on field programmable gate array chip (FPGA), a flat top forming algorithm with optimal filtering shaping effect and a symmetrical zero area forming algorithm with low dead time pulse processing effect are realized in parallel, and ultimately meet the requirements of the detection system for measurement speed and measurement accuracy, so as to provide a theoretical basis for the optimal design of the in-site X-ray detector based on the silicon drift detector, and provides technical support for the accurate and rapid investigation of field mineral resources.
现场X荧光探测作为核地球物理勘探领域的重要技术方法,在地质矿物资源开发中发挥着重要的作用。由于传统的X荧光探测仪具有检出限高、死时间长、在高计数率条件下系统能量分辨率显著下降的缺点,因此无法通过增加荧光产额的方法缩短测量周期,无法对矿物实现精确快速测量。针对该问题,本项目拟基于新型硅漂移探测器,构建完整的硅漂移X荧光探测数学模型,建立探测器能量响应函数,对高分辨率硅漂移探测器技术、高速低噪声信号读出技术、全数字化高速核脉冲采集处理技术进行研究,并基于现场可编程门阵列芯片(FPGA)并行实现具有最佳滤波成形效果的平顶成形算法和具有低死时间脉冲处理效果的对称零面积成形算法,最终使探测系统满足测量速度和测量精度的要求,从而为基于硅漂移探测器的现场X荧光探测仪的最优化设计提供理论依据,为野外矿产资源的精确快速勘察提供技术保障。
结项摘要
硅漂移探测器(SDD)是一种具有高能量分辨率和高脉冲通过率的半导体探测器,在现场X荧光探测领域中发挥着重要的作用。本项目针对SDD探测器能量沉积和载流子传输特点,开展了探测器前置读出电路、谱仪电路和数字核脉冲处理算法的设计。其中前置读出电路方面,分别研制了源级复位型电荷灵敏前置放大器、开关并联复位型电荷灵敏前置放大器、基于Cube ASIC的电荷灵敏前置放大器,实现硅漂移探测器高速、低噪声信号的读出;谱仪电路方面,研制了数字高速核脉冲处理器,其电路模拟带宽为100MHz、采样率为80MSPS,可实现核脉冲信号的低噪声、高通过率、高精度的测量;数字核脉冲处理算法方面,分别开展了适用于复位型前置读出电路的数字化预调理、数字化核脉冲信号最优滤波等算法的研究,并在嵌入式核脉冲处理器上实现了平顶成形、对称零面积成形、数字CR微分、数字极零相消、数字恒比定时、数字基线恢复等算法。基于上述读出电路、谱仪电路、核脉冲处理算法可实现硅漂移探测器快速、高精度的能谱测量,为高端国产核仪器装备的研制提供技术支撑。
项目成果
期刊论文数量(9)
专著数量(0)
科研奖励数量(2)
会议论文数量(0)
专利数量(3)
Study on gamma spectrum wavelet noise reduction based on scintillation detector
基于闪烁探测器的伽马能谱小波降噪研究
- DOI:10.1088/1742-6596/1941/1/012027
- 发表时间:2021
- 期刊:Journal of Physics: Conference Series
- 影响因子:--
- 作者:Yingchi Yu;Liangquan Ge;Fei Li;Chuanhao Hu
- 通讯作者:Chuanhao Hu
Spectral data processing based on maximum noise fraction
基于最大噪声分数的光谱数据处理
- DOI:10.1088/1742-6596/1941/1/012028
- 发表时间:2021
- 期刊:Journal of Physics: Conference Series
- 影响因子:--
- 作者:Wentai Guo;Liangquan Ge;Fei Li;Chuanhao Hu
- 通讯作者:Chuanhao Hu
小波包软阈值降噪法在航空γ能谱中的应用
- DOI:10.11889/j.0253-3219.2022.hjs.45.090501
- 发表时间:2022
- 期刊:核技术
- 影响因子:--
- 作者:张松;胡传皓;李承洋;王楠;严磊;李雪刚;曾国强;顾民
- 通讯作者:顾民
Study of a full-digital multi-waveform nuclear pulse signal generator
全数字多波形核脉冲信号发生器的研究
- DOI:10.1016/j.apradiso.2021.110028
- 发表时间:2022
- 期刊:Applied Radiation and Isotopes
- 影响因子:1.6
- 作者:Ming Xiao;Rui Hu;Liangquan Ge;Chuan-Hao Hu
- 通讯作者:Chuan-Hao Hu
BGO闪烁体电流前置放大器设计
- DOI:--
- 发表时间:2022
- 期刊:核电子学与探测技术
- 影响因子:--
- 作者:曹杨;胡传皓;喻川;李雪刚;胡世敏;胡瑶函;段志强;白彬;曾国强
- 通讯作者:曾国强
数据更新时间:{{ journalArticles.updateTime }}
{{
item.title }}
{{ item.translation_title }}
- DOI:{{ item.doi || "--"}}
- 发表时间:{{ item.publish_year || "--" }}
- 期刊:{{ item.journal_name }}
- 影响因子:{{ item.factor || "--"}}
- 作者:{{ item.authors }}
- 通讯作者:{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ patent.updateTime }}
其他文献
Si-PIN与CdTe探测器应用于X射线荧光能谱测量的研究
- DOI:--
- 发表时间:2017
- 期刊:光谱学与光谱分析
- 影响因子:--
- 作者:胡传皓;曾国强
- 通讯作者:曾国强
手持式单板500MHz采样率数字化多道设计
- DOI:--
- 发表时间:2017
- 期刊:核技术
- 影响因子:--
- 作者:曾国强;欧阳晓平;喻明福;李强;魏世龙;胡传皓;杨剑;葛良全
- 通讯作者:葛良全
基于高速电流脉冲前放的数字式电荷积分型能谱仪系统设计
- DOI:10.13715/j.cnki.nsjxu.2018.04.007
- 发表时间:2018
- 期刊:湘潭大学自然科学学报
- 影响因子:--
- 作者:曾国强;盛磊;卿松;严磊;胡传皓;杨寿南;葛良全
- 通讯作者:葛良全
Research and development of a high-performance differential-hybrid charge sensitive preamlifier
高性能差分混合电荷敏感前置放大器的研发
- DOI:--
- 发表时间:2017
- 期刊:Applied Radiation and Isotopes
- 影响因子:1.6
- 作者:曾国强;胡传皓
- 通讯作者:胡传皓
其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:{{ item.doi || "--" }}
- 发表时间:{{ item.publish_year || "--"}}
- 期刊:{{ item.journal_name }}
- 影响因子:{{ item.factor || "--" }}
- 作者:{{ item.authors }}
- 通讯作者:{{ item.author }}
内容获取失败,请点击重试
查看分析示例
此项目为已结题,我已根据课题信息分析并撰写以下内容,帮您拓宽课题思路:
AI项目摘要
AI项目思路
AI技术路线图
请为本次AI项目解读的内容对您的实用性打分
非常不实用
非常实用
1
2
3
4
5
6
7
8
9
10
您认为此功能如何分析更能满足您的需求,请填写您的反馈:
相似国自然基金
{{ item.name }}
- 批准号:{{ item.ratify_no }}
- 批准年份:{{ item.approval_year }}
- 资助金额:{{ item.support_num }}
- 项目类别:{{ item.project_type }}
相似海外基金
{{
item.name }}
{{ item.translate_name }}
- 批准号:{{ item.ratify_no }}
- 财政年份:{{ item.approval_year }}
- 资助金额:{{ item.support_num }}
- 项目类别:{{ item.project_type }}