CONDUCTANCE TELEMETRY SYSTEM FOR IMPLANTED BLOOD PUMPS

植入式血泵电导遥测系统

基本信息

项目摘要

DESCRIPTION: (Adapted from the applicants' abstract). Next-generation implantable blood pumps will not include tubes or wires passing through the skin. Yet patient safety demands that malfunctions occurring in the implanted components be communicated to the patient so that action can be taken to minimize risk. Since information cannot be carried on percutaneous wires, the information must be telemetered. The goal of this program is to develop a new means for maintaining bi-directional communications between the implanted components and the external components of next-generation left ventricular assist devices and artificial hearts. The link from the implanted components to the external components is to be suitable for use in alarm strategies and for stored information retrieval. The link from external components to internal components is to be suitable for use in system reprogramming and initiating data retrieval. This new means of transmitting information will be referred to as "conductance telemetry." The ECG signal is a naturally occurring form of conductance telemetry. Information about the condition of the heart is present in voltage differences measurable at the skin surface. The proposed telemetry system uses the same principle to make information about the condition of an implanted blood pump detectable at the skin surface, without interfering with conventional recordings of bioelectric signals. PROPOSED COMMERCIAL APPLICATION: NOT AVAILABLE
描述:(改编自申请人的摘要)。下一代 可植入的血泵将不包括通过 皮肤。然而,患者的安全要求植入了故障 将组件传达给患者,以便可以采取行动 最小化风险。由于信息无法在经皮线上携带 信息必须进行遥测。 该计划的目的是开发一种维护新的手段 植入组件与外部的双向通信 下一代左心室辅助设备和人造的组件 心。从植入的组件到外部组件的链接是 适合用于警报策略和存储信息检索。 从外部组件到内部组件的链接适合 用于系统重编程和启动数据检索。这种新的手段 传输信息将称为“电导遥测”。 ECG信号是一种天然发生的电导遥测形式。 关于心脏状况的信息存在于电压差异 在皮肤表面可测量。提出的遥测系统使用相同 制作有关植入血泵状况的信息的原理 可在皮肤表面检测到,而不会干扰常规 生物电信号的记录。 拟议的商业应用程序:不可用

项目成果

期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)

暂无数据

数据更新时间:2024-06-01

CRAIG W SHERMAN的其他基金

Vehicular power adapter for implanted blood pumps
用于植入式血泵的车载电源适配器
  • 批准号:
    6833630
    6833630
  • 财政年份:
    2004
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
A conductance telemetry system for implant blood pumps
用于植入血泵的电导遥测系统
  • 批准号:
    6527400
    6527400
  • 财政年份:
    1999
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
A conductance telemetry system for implant blood pumps
用于植入血泵的电导遥测系统
  • 批准号:
    6404712
    6404712
  • 财政年份:
    1999
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
A TRANSCUTANEOUS POWER SYSTEM FOR ROTARY BLOOD PUMPS
用于旋转式血泵的经皮动力系统
  • 批准号:
    6015670
    6015670
  • 财政年份:
    1998
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
TRANSCUTANEOUS POWER SYSTEM FOR ROTARY BLOOD PUMPS
用于旋转式血泵的经皮动力系统
  • 批准号:
    2715421
    2715421
  • 财政年份:
    1998
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
A TRANSUTANEOUS POWER SYSTEM FOR ROTARY BLOOD PUMPS
旋转式血泵的跨超声电源系统
  • 批准号:
    6184773
    6184773
  • 财政年份:
    1998
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:

相似海外基金

DEVELOPMENT OF INNOVATIVELY SUSPENDED TESLA PUMP LVAD
创新悬挂式特斯拉泵 LVAD 的开发
  • 批准号:
    7091171
    7091171
  • 财政年份:
    2006
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
Small Non-Thrombogenic Rotary Mag Lev LVAD
小型非血栓旋转磁升压 LVAD
  • 批准号:
    6889588
    6889588
  • 财政年份:
    2004
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
Small Non-Thrombogenic Rotary Mag Lev LVAD
小型非血栓旋转磁升压 LVAD
  • 批准号:
    6793773
    6793773
  • 财政年份:
    2004
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
Fully Implantable Mini-Mixed-Flow Pump
完全植入式微型混流泵
  • 批准号:
    7060583
    7060583
  • 财政年份:
    2004
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别:
Development of a Pediatric pVAD
儿科 pVAD 的开发
  • 批准号:
    6833856
    6833856
  • 财政年份:
    2004
  • 资助金额:
    $ 9.14万
    $ 9.14万
  • 项目类别: