DIGITAL MAMMOGRAPHY HIGH RESOLUTION FLAT PANEL IMAGER
数字乳腺X线摄影高分辨率平板成像仪
基本信息
- 批准号:6633865
- 负责人:
- 金额:$ 50.55万
- 依托单位:
- 依托单位国家:美国
- 项目类别:
- 财政年份:2001
- 资助国家:美国
- 起止时间:2001-07-01 至 2006-06-30
- 项目状态:已结题
- 来源:
- 关键词:
项目摘要
DESCRIPTION (Adapted from Applicant's Abstract): This is a Bioengineering
Research Partnership between UMass Medical School and Lockheed-Martin
Corporation. It is aimed at developing and evaluating a new high resolution
flat panel mammographic imager with a variable pixel size (40 microns and 80
microns) using tiled charged-coupled devices (CCD). The detector will cover an
area essentially the same as the sensitive area of a conventional mammographic
cassette. The specific hypotheses are: (a) the new imager will exhibit better
detective quantum efficiency (DQE) than current screen-film technology. (b)
Unlike current screen-film, the system will exhibit higher dynamic range. (c)
The spatial resolution will be higher than current flat-panel imaging systems
due to the smaller pixel size and 100 percent fill factor. (d) The contrast
will be significantly better than existing screen-film systems resulting in
better visualization of breast anatomy at a reduced radiation dose to the
patient due to the improved DQE. (e) A well-designed mammographic system driven
in an optimized acquisition mode will replace screen-film systems for
full-breast mammographic imaging. Preliminary computational and experimental
studies suggest that a CCD flat panel detector of this type is feasible. The
experimental plan calls for comprehensive evaluation of the characteristics of
the detector and evaluation of the system though objective and universally
accepted metrics such as the spatially dependent modulation transfer function
and DQE. The applicants report experience with the 100 micron pixel GE clinical
evaluation prototype in a screening population, which appears to demonstrate
equivalency for cancer detection with similar sensitivities. However, there are
concerns about of the more subtle forms of calcifications such as punctate and
amorphous. When calcium is seen the edge sharpness does not appear to have the
same sharpness as that of spot film views. These problems may be related to the
relatively large pixel size (100 microns) of the detector. The applicants
propose to develop and evaluate the next generation of high resolution digital
mammography with high spatial resolution and without the detrimental loss in
the signal-to-noise ratio, which is common with the older generation, which
uses demagnifying fiberoptics. The proposed prototype using an array of
seamlessly tiled CCDs coupled to a structured CsI:TI scintillator by a
non-tapering fiberoptic plate will deliver the highest resolution than any
other flat panel mammographic detector.
描述(改编自申请人的摘要):这是一项生物工程
麻省大学医学院与洛克希德·马丁公司之间的研究合作
公司。它旨在开发和评估新的高分辨率
具有可变像素尺寸(40 微米和 80 微米)的平板乳腺 X 线成像仪
微米),使用平铺电荷耦合器件(CCD)。探测器将覆盖
区域与传统乳腺X线摄影的敏感区域基本相同
盒式磁带。具体假设是:(a)新成像仪将表现出更好的性能
侦探量子效率 (DQE) 高于当前的屏幕胶片技术。 (二)
与当前的屏幕胶片不同,该系统将表现出更高的动态范围。 (三)
空间分辨率将高于当前的平板成像系统
由于较小的像素尺寸和 100% 的填充因子。 (d) 对比
将明显优于现有的屏幕胶片系统
在减少辐射剂量的情况下更好地观察乳房解剖结构
由于 DQE 的改善,患者得到了改善。 (e) 精心设计的乳腺X线摄影系统驱动
在优化的采集模式下将取代屏幕胶片系统
全乳腺乳房X线摄影成像。初步计算和实验
研究表明这种类型的 CCD 平板探测器是可行的。这
实验计划要求综合评估特征
系统的检测和评估客观且普遍
可接受的指标,例如空间相关的调制传递函数
和 DQE。申请人报告了 100 微米像素 GE 临床的经验
筛选人群中的评估原型,这似乎表明
具有相似灵敏度的癌症检测的等效性。然而,有
担心更微妙的钙化形式,例如点状和
无定形。当看到钙时,边缘清晰度似乎没有
与现场电影视图的清晰度相同。这些问题可能与
探测器的像素尺寸相对较大(100 微米)。申请人
建议开发和评估下一代高分辨率数字
乳腺X线摄影具有高空间分辨率并且不会造成有害的损失
信噪比,这在老一代中很常见,
使用缩小光纤。所提出的原型使用一系列
无缝平铺的 CCD 通过一个耦合器与结构化 CsI:TI 闪烁体耦合
非锥形光纤板将提供比任何
其他平板乳腺X线摄影探测器。
项目成果
期刊论文数量(5)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
Computation of the glandular radiation dose in digital tomosynthesis of the breast.
乳房数字断层合成中腺体辐射剂量的计算。
- DOI:
- 发表时间:2007-01
- 期刊:
- 影响因子:3.8
- 作者:Sechopoulos, Ioannis;Suryanarayanan, Sankararaman;Vedantham, Srinivasan;D'Orsi, Carl;Karellas, Andrew
- 通讯作者:Karellas, Andrew
Evaluation of an improved algorithm for producing realistic 3D breast software phantoms: application for mammography.
评估用于生成逼真 3D 乳房软件模型的改进算法:乳房 X 线摄影应用。
- DOI:
- 发表时间:2010-11
- 期刊:
- 影响因子:3.8
- 作者:Bliznakova, K;Suryanarayanan, S;Karellas, A;Pallikarakis, N
- 通讯作者:Pallikarakis, N
Breast cancer imaging: a perspective for the next decade.
乳腺癌成像:未来十年的展望。
- DOI:
- 发表时间:2008-11
- 期刊:
- 影响因子:3.8
- 作者:Karellas, Andrew;Vedantham, Srinivasan
- 通讯作者:Vedantham, Srinivasan
Scatter radiation in digital tomosynthesis of the breast.
乳房数字断层合成中的散射辐射。
- DOI:
- 发表时间:2007-02
- 期刊:
- 影响因子:3.8
- 作者:Sechopoulos, Ioannis;Suryanarayanan, Sankararaman;Vedantham, Srinivasan;D'Orsi, Carl J;Karellas, Andrew
- 通讯作者:Karellas, Andrew
Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast.
对乳房专用 CT 对身体的辐射剂量进行蒙特卡罗和体模研究。
- DOI:
- 发表时间:2008-04
- 期刊:
- 影响因子:19.7
- 作者:Sechopoulos, Ioannis;Vedantham, Srinivasan;Suryanarayanan, Sankararaman;D'Orsi, Carl J;Karellas, Andrew
- 通讯作者:Karellas, Andrew
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
Andrew Karellas其他文献
Andrew Karellas的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('Andrew Karellas', 18)}}的其他基金
Upright, Low-dose, High-resolution, 3D Breast CT
立式、低剂量、高分辨率、3D 乳腺 CT
- 批准号:
9810897 - 财政年份:2019
- 资助金额:
$ 50.55万 - 项目类别:
High-resolution lower dose dedicated breast CT
高分辨率低剂量专用乳腺 CT
- 批准号:
9925061 - 财政年份:2017
- 资助金额:
$ 50.55万 - 项目类别:
DIGITAL MAMMOGRAPHY HIGH RESOLUTION FLAT PANEL IMAGER
数字乳腺X线摄影高分辨率平板成像仪
- 批准号:
6514778 - 财政年份:2001
- 资助金额:
$ 50.55万 - 项目类别:
DIGITAL MAMMOGRAPHY HIGH RESOLUTION FLAT PANEL IMAGER
数字乳腺X线摄影高分辨率平板成像仪
- 批准号:
6215932 - 财政年份:2001
- 资助金额:
$ 50.55万 - 项目类别:
HIGH RESOLUTION CARDIOVASCULAR FLAT-PANEL X-RAY IMAGER
高分辨率心血管平板 X 射线成像仪
- 批准号:
6704089 - 财政年份:2000
- 资助金额:
$ 50.55万 - 项目类别:
HIGH RESOLUTION CARDIOVASCULAR FLAT-PANEL X-RAY IMAGER
高分辨率心血管平板 X 射线成像仪
- 批准号:
6390861 - 财政年份:2000
- 资助金额:
$ 50.55万 - 项目类别:
相似国自然基金
智能控释硫化氢的脂质体水凝胶构建及其抑制骨关节炎病理性钙化的研究
- 批准号:32301116
- 批准年份:2023
- 资助金额:30 万元
- 项目类别:青年科学基金项目
JCAD负调控Osteopontin促血管钙化的作用和机制研究
- 批准号:82300485
- 批准年份:2023
- 资助金额:30 万元
- 项目类别:青年科学基金项目
PFKFB3驱动的血管平滑肌细胞糖酵解促进慢性肾病血管钙化的作用和机制研究
- 批准号:82370421
- 批准年份:2023
- 资助金额:49 万元
- 项目类别:面上项目
衰老脑组织来源细胞外微囊泡促进动脉中膜钙化的机制研究
- 批准号:82370892
- 批准年份:2023
- 资助金额:49 万元
- 项目类别:面上项目
Y型细胞周期蛋白调控血管平滑肌细胞促进血管钙化的作用及机制研究
- 批准号:82370412
- 批准年份:2023
- 资助金额:49 万元
- 项目类别:面上项目
相似海外基金
X-ray imaging using edge-on-microchannel plate detectors
使用边缘微通道板探测器进行 X 射线成像
- 批准号:
7061611 - 财政年份:2003
- 资助金额:
$ 50.55万 - 项目类别:
X-ray imaging using edge-on-microchannel plate detectors
使用边缘微通道板探测器进行 X 射线成像
- 批准号:
6884583 - 财政年份:2003
- 资助金额:
$ 50.55万 - 项目类别:
X-ray imaging using edge-on-microchannel plate detectors
使用边缘微通道板探测器进行 X 射线成像
- 批准号:
6752518 - 财政年份:2003
- 资助金额:
$ 50.55万 - 项目类别:
X-ray imaging using edge-on-microchannel plate detectors
使用边缘微通道板探测器进行 X 射线成像
- 批准号:
6687451 - 财政年份:2003
- 资助金额:
$ 50.55万 - 项目类别:
DIGITAL MAMMOGRAPHY HIGH RESOLUTION FLAT PANEL IMAGER
数字乳腺X线摄影高分辨率平板成像仪
- 批准号:
6514778 - 财政年份:2001
- 资助金额:
$ 50.55万 - 项目类别: